How thick should an explosion proof wall be?

If you’ve ever stood on the edge of an industrial plant design meeting, listening to engineers bicker over load calculations and safety margins, you know one question always rises to the surface: How thick should an explosion proof wall be? As a supplier of these walls for nearly 12 years, I’ve fielded this question every single week—from refinery maintenance managers trying to meet OSHA’s latest standards to chemical plant designers adjusting layouts to fit tight footprints. The short answer isn’t a number you can pull off a spec sheet; it’s a formula tied to the risk you’re mitigating, the materials you’re protecting, and the regulations that keep teams safe. Let’s break this down without the jargon, because at the end of the day, this thickness is a balance between protecting lives and keeping operations running. Explosion Proof Wall

First, let’s start with what an explosion proof wall actually does, because that’s where the confusion sets in. Too many people call them “bulletproof walls” or “blast walls,” but they’re not the same. A blast wall stops high-pressure shockwaves from a detonation; an explosion proof wall (often labeled a deflagration barrier or blast resistant wall) contains the initial explosion, keeps fire and debris from spreading, and prevents secondary blasts that are often deadlier than the first. For context, a deflagration is a slower, burning explosion (like a gas leak igniting in a confined space) that travels at subsonic speeds, while a detonation is a supersonic blast that hits like a freight train—usually from explosives or highly volatile materials. The thickness you need shifts dramatically between these two, and that’s where I’ve seen most suppliers cut corners.

Let’s talk about the core variables that drive thickness, because no one-size-fits-all exists. The biggest factor is the overpressure rating: that’s the maximum force the wall has to withstand, measured in pounds per square inch (psi). For low-risk areas, like storage closets for non-flammable cleaning supplies, you might only need a 4-inch wall rated for 2 psi. But for a refinery’s processing unit where hydrogen gas is stored, overpressure can hit 15 psi or more, and thickness jumps to 12 to 18 inches. Wait, why such a range? It’s not just psi—there’s also the standoff distance, which is how far the explosion is from the wall. If an explosion occurs 50 feet away from a wall, the shockwave dissipates, so you can use a thinner wall than if it’s 10 feet away. I once worked on a job where a plant wanted to move a gas storage tank from 20 feet from an office break room to 8 feet away; we had to increase the wall thickness from 8 inches to 14 inches to match the new overpressure risk.

Another variable is the construction material. Most people assume concrete is the only option, but that’s not true for every site. Lightweight concrete, which has aggregates like expanded shale, is half the weight of regular concrete, but its blast resistance is lower. For a warehouse where floor load is a concern (many old industrial floors can’t support heavy walls), we often recommend fiber-reinforced concrete with a foam core. That cuts weight by 30% and maintains the same overpressure rating as regular concrete—so a 10-inch lightweight fiber wall equals a 12-inch regular concrete wall. For extreme high-risk areas, like ammo depots or chemical manufacturing facilities handling nitroglycerin, we use composite panels with steel facings and a cementitious core, which can withstand 30 psi and needs only 16 inches thickness—way thinner than a solid concrete wall of the same rating, and easier to install.

Then there’s the building codes and standards that dictate this, because this isn’t guesswork. I’ve seen too many contractors try to use a 6-inch wall for a 10 psi risk, only to fail OSHA inspections. The main standards we follow are from the National Fire Protection Association (NFPA), the Occupational Safety and Health Administration (OSHA), and the American Society of Civil Engineers (ASCE). NFPA 68, which covers deflagration protection, outlines that walls in Class I, Division 1 areas (where flammable gases or vapors are present regularly) need to be rated for at least 10 psi, with a minimum thickness of 8 inches. ASCE 7, which deals with blast loads, is more specific for structural walls: it calculates overpressure based on the type of explosion, distance, and duration, then maps the required thickness. I always tell clients not to ignore these codes—last year, we had a client who skipped ASCE 7 for a 20 psi risk and went with an 18-inch concrete wall, which was actually overkill and cost them $20,000 extra. The right thickness would have been 14 inches, per ASCE calculations.

Wait, but what about walls that aren’t attached to a building’s structure? That’s another mistake I see. If the explosion proof wall is a standalone unit, not part of the plant’s existing framework, you have to account for the fact that it can’t rely on adjacent walls for support. For a standalone wall, the thickness is usually 2 to 3 inches more than a wall that’s tied into the main structure. A few years back, we supplied standalone walls for a temporary storage yard for propane tanks; the client wanted 12-inch walls for 15 psi, but our engineers pushed for 15 inches because they were standalone. When we did a test blast simulation, the 12-inch wall would have tipped over from the shockwave, while the 15-inch held. That’s a case where “thicker is better” isn’t the rule, but not accounting for installation type is.

Now, let’s get to the myth that thicker is always safer. I’ve had clients come in asking for 30-inch walls because they “want extra protection,” and it’s rarely necessary. The problem with overly thick walls is twofold: first, they’re way more expensive, and second, they can create a hazard of their own. If a wall is too heavy, it can collapse during a blast and send concrete shrapnel flying—deadly debris that’s often more dangerous than the initial shockwave. I remember a 2019 incident at a chemical plant where a contractor had installed a 24-inch concrete wall for a 10 psi risk; when a small gas explosion occurred, the wall cracked and sent chunks of concrete into a nearby break room, killing two workers. The correct thickness for that risk would have been 10 inches, which would have contained the blast without creating shrapnel. That’s why we always do a site assessment first— we measure the area’s risk, check the floor load capacity, confirm the attachment points, and run blast simulations before recommending a thickness.

So, what’s the takeaway for someone who’s trying to figure out their own wall thickness? It’s not a number you can pull out of thin air. Start with these steps: first, identify the hazard level. Is your area Class I, Division 1 (high risk, flammable materials present) or Class I, Division 2 (moderate risk, only occasional flammable material exposure)? Second, measure the distance between the explosion source and the wall. Third, confirm which codes apply to your industry—refineries follow different rules than food processing plants handling dust explosions. Fourth, talk to a supplier who specializes in explosion proof walls, not a general contractor who might not be up to date on the latest regulations. At the end of the day, a 1-inch error in thickness might seem small, but it can mean the difference between a minor incident and a catastrophic loss.

If you’re in the market for an explosion proof wall and need a precise, code-compliant thickness calculation tailored to your site, we’re here to help. Reach out to our team to discuss your project, share the details of your facility’s layout and risk level, and we’ll provide a customized solution that balances safety, cost, and functionality.

Slope Netting References

  1. National Fire Protection Association (NFPA). NFPA 68: Standard on Explosion Protection by Deflagration Venting. National Fire Protection Association, 2021.
  2. Occupational Safety and Health Administration (OSHA). 29 CFR 1910.155: Hazardous Locations. U.S. Department of Labor, 2022.
  3. American Society of Civil Engineers (ASCE). ASCE 7-22: Minimum Design Loads and Associated Criteria for Buildings and Other Structures. American Society of Civil Engineers, 2022.
  4. American Institute of Chemical Engineers (AIChE). Guidelines for Vapor Cloud Explosion Pressure, and Isolated Blasting. American Institute of Chemical Engineers, 2020.